Coaxial Cable MIL-C-17 QPL

DESCRIPTION:
DESCRIPTION: PREMIUM GRADE COAXIAL CABLES MANUFACTURED IN STRICT ACCORDANCE WITH MIL-C-17. ALL CABLES LISTED ARE SUPPLIED BY MANUFACTURERS ON A QUALIFIED PRODUCT LIST ISSUED BY THE U.S. GOVERNMENT DEFENSE INDUSTRIAL SUPPLY CENTER.
📱 Swipe left/right to view all table columns
JAGUAR CATALOG NO. MIL-C-17 DESIGNATION DWG REPLACES CONDUCTOR TYPE & CORE O.D. SHIELD(S) JACKET MAT. & O.D. NOM. IMP. OHM TEMP RANGE °C MAX. CAP. PF/FT MAX. WORK VOLT. MAX. WT. /100 FT.
JM17-29 M17/29-RG59 A RG59/U CCS .0226 | PE .146 1 BC PVCN .242 75 -40 + 85 20.0 1,700 3.50
JM17-60 M17/60-RG142 B RG142B/U SCCS.037 | PTFE.116 2 SPC FEP .195 50 -55 + 200 29.3(N) 1,400 4.30(N)
JM17-75 M17/75-RG214 B RG214/U SPC 7x.0296 | PE .285 2 SPC PVCN .425 50 -40 + 85 32.2 3,700 13.0
JM17-86 M17/86-00001 B RG225/U SPC 7x.0312 | PTFE .285 2 SPC FG BRD .430 50 -55 + 200 29.4 5,000 19.5
JM17-90 M17/90-RG71 D RG71B/U CCS .0253 | AIR/POLY.146 2 BC PE .245 93 -55 + 85 14.5 750 5.00
JM17-930 M17/93-RG178 A RG178/U SCCS 7x.004 | PTFE .033 1 SPC FEP .071 50 -55 + 200 32.0 750 .625
JM17-931 M17/93-00001 A M17/140-00001 SCCS 7x.004 | PTFE.033 1 SPC PFA .071 50 -55 + 230 32.0 750 .625
JM17-94 M17/94-RG179 A RG179/U SCCS 7x.004 | PTFE.063 1 SPC FEP .100 75 -55 + 200 23.0 900 1.08
JM17-95 M17/95-RG180 A RG180/U SCCS 7x.004 | PTFE .102 1 SPC FEP .141 95 -55 + 200 17.4 1,100 1.98
JM17-110 M17/110-RG302 A RG302/U SCCS .0253 | PTFE .146 1 SPC FEP .202 75 -55 + 200 22.0 1,700 4.00
JM17-111 M17/111-RG303 A RG303/U SCCS.037 | PTFE.116 1 SPC FEP .170 50 -55 + 200 32.0 1,400 3.10
JM17-112 M17/112-RG304 B RG304/U SCCS.059 | PTFE.185 2 SPC FEP .280 50 -55 + 200 32.0 2,200 4.50
JM17-113 M17/113-RG316 A M17/69RG316/U SCCS 7x.0067 | PTFE .060 1 SPC FEP .098 50 -55 + 200 32.0 900 1.22
JM17-127 M17/127-RG393 B RG393/U SCCS 7x.0312 | PTFE .285 2 SPC FEP .390 50 -55 + 200 29.4 1,875 17.5
JM17-128 M17/128-RG400 B RG400/U SPC 19x.008 | PTFE .116 2 SPC FEP .195 50 -55 + 200 32.0 1,400 5.00
JM17-1290 M17/129-RG401 H RG401/U SPC .0641 | PTFE .209 COPPER + TUBE NONE .250 50 -40 + 90 29.6 3,000 10.5
JM17-1300 M17/130-RG402 H RG402/U SCCS .0362 | PTFE .1175 COPPER + TUBE NONE .141 50 -40 + 125 29.9 1,900 34.4
JM17-1301 M17/130-00001 H SCCS .0362 | PTFE .1175 TC TUBE NONE .141 50 -40 + 125 29.9 1,900 35.1
JM17-1302 M17/130-00002 H NCCS .0362 | PTFE .1175 COPPER + TUBE NONE .141 50 -40 + 125 29.9 1,900 34.4
JM17-1303 M17/130-00003 H NCCS .0362 | PTFE .1175 TC TUBE NONE .141 50 -40 + 125 29.9 1,900 35.1
JM17-13012 M17/130-00012 H SCCS .0362 | PTFE .1175 SPC TUBE NONE .141 50 -40 + 125 29.9 1,900 35.1
JM17-131 M17/131-RG403 E RG403/U SCCS 7x.004 | PTFE .033 1 SPC + + FEP+TAPE FEP .116 50 -55 + 200 30.2160 750300 1.65
JM17-1330 M17/133-RG405 H RG405/U SCCS .0201 | PTFE .066 COPPER + TUBE NONE .0865 50 -40 + 125 32.0 1,500 15.3
JM17-1331 M17/133-00001 H SCCS .0201 | PTFE .066 TC TUBE NONE .0865 50 -40 + 125 32.0 1,500 15.8
JM17-1332 M17/133-00002 H SPC .0201 | PTFE .066 COPPER + TUBE NONE .0865 50 -40 + 125 32.0 1,500 15.2
JM17-1333 M17/133-00003 H SPC .0201 | PTFE .066 TC TUBE NONE .0865 50 -40 + 125 32.0 1,500 15.7
JM17-1361 M17/136-00001 A SCCS 7x.004 | PTFE.063 1 SPC PFA .100 75 -55 + 230 22.0 900 1.20
JM17-1371 M17/137-00001 A SCCS 7x.004 | PTFE .102 1 SPC PFA .141 95 -55 + 200 15.4 1,100 2.00
JM17-1381 M17/138-00001 A SCCS 7x.0087 | PTFE .060 1 SPC PFA .098 50 -55 + 230 32.0 900 1.22
JM17-1581 M17/158-00001 B RG142B/U SCCS .037 | PTFE .115 2 SPC FEP .195 50 -55 + 200 32.0 1,400 5.60
JM17-1641 M17/164-00001 B RG214/U SPC 7x.0296 | PE .285 2 SPC PVC .425 50 -40 + 85 32.2 3,700 14.0
JM17-1691 M17/169-00001 A RG178B/URG196A/U SCCS 7x.004 | PTFE .033 1 SPC FEP .071 50 -55 + 200 32.0 750 .630
JM17-1701 M17/170-00001 A RG303/URG141/U SCCS .037 | PTFE .116 1 SPC FEP .170 50 -55 + 200 32.0 1,400 3.90
JM17-1711 M17/171-00001 B RG304/U SCCS .059 | PTFE .185 2 SPC FEP .280 50 -55 + 200 32.0 2,200 9.24
JM17-1721 M17/172-00001 A RG316/URG188/U SCCS 7x.0067 | PTFE .060 1 SPC FEP .098 50 -55 + 200 32.0 900 1.15
JM17-1741 M17/174-00001 B RG393/U SPC 7x.0312 | PTFE.285 2 SPC FEP .390 50 -55 + 200 32.0 1,875 17.5
JM17-1751 M17/175-00001 B RG400/U SPC 19x.008 | PTFE.116 2 SPC FEP .195 50 -55 + 200 32.0 1,400 5.00
JM17-1762 M17/176-00002 F M17/176-00001 SPECIAL (2) | PTFE 1 SPC + ALLOY PFA .129 77 -55 + 200 24.0 750 18.0
JM17-1811 M17/181-00001 G M17/6RG11/U TC 7x.0159 | POLY.285 1 BC CLP .405 75 -30 + 85 22.0 3,700 10.8
JM17-1831 M17/183-00001 G M17/28RG58 TC 19x.0072 | POLY.116 1 TC CLP .195 50 -30 + 85 32.2 1,400 3.00
JM17-1841 M17/184-00001 G M17/29RG59 CCS .0226 | PE .146 1 BC CLP .242 75 -30 + 85 22.0 1,700 4.3
JM17-1851 M17/185-00001 J M17/30RG62/U CCS.0253 | AIR/POLY.146 1 BC CLP .242 93 -30 + 85 14.5 750 4.20
JM17-1891 M17/189-00001 G M17/74RG213 BC 7x.0296 | POLY .285 1 BC CLP .405 50 -30 + 85 32.2 3,700 12.1
JM17-1901 M17/190-00001 K M17/75RG214 SPC 7x.0296 | PE .285 2 SPC CLP .425 50 -30 + 85 32.2 3,700 15.4
JM17-1941 M17/194-00001 K M17/84RG223 SPC .035 | POLY .116 2 SPC CLP .212 50 -30 + 85 32.2 1,400 4.0
JM17-1971 M17/197-00001 G M17/155-00001RG58C/U TC 19x.0072 | POLY .116 1 TC CLP .195 50 -30 + 85 32.2 1,400 3.1

About Coaxial Cable MIL-C-17 QPL

Jaguar Industries' MIL-C-17 QPL qualified coaxial cables represent the highest standard in military and aerospace-grade RF transmission cables. These Qualified Products List approved cables meet stringent MIL-C-17 specifications for critical defense, aerospace, and high-reliability applications. Featuring advanced construction with silver coated copper steel (SCCS), silver plated copper (SPC), tinned copper (TC), bare copper (BC), and copper clad steel (CCS) conductors, these cables deliver exceptional performance across extreme temperature ranges from -55°C to +230°C. Dielectric materials include PTFE (polytetrafluoroethylene), FEP (fluorinated ethylene propylene), PFA (perfluoroalkoxy), CLP (chlorinated polyethylene), and polyethylene, providing superior insulation properties and signal integrity. Shielding configurations range from single SPC/TC/BC to double SPC layers, with specialized options including copper tube and alloy shields for maximum EMI/RFI protection. Available impedances include 50 ohm, 75 ohm, 77 ohm, 93 ohm, and 95 ohm configurations to match specific system requirements. These cables replace legacy RG-series cables including RG403/U, RG405/U, RG142B/U, RG214/U, RG178B/U, RG196A/U, RG303/U, RG141/U, RG304/U, RG316/U, RG188/U, RG393/U, RG400/U, RG11/U, RG58, RG59, RG62/U, RG213, RG223, and RG58C/U with enhanced performance characteristics. Maximum working voltages range from 750V to 3,700V, with capacitance values optimized for low signal loss. Drawing designations A through K indicate different construction standards and specifications. Ideal for military aircraft, spacecraft, radar systems, missile guidance, naval communications, ground-based defense electronics, satellite systems, and any application requiring QPL-approved cables with proven reliability in extreme environments. Custom configurations and additional MIL-C-17 designations available upon request.