Description: The following cables are used for high temperature applications or where plenum rated cable is specified
DESIGNATION | DRAW ING |
JAGUAR CATALOG NO. |
CONDUCTOR TYPE & CORE O.D. |
SHIELD(S) | JACKET MAT. &O.D. |
NOM. IMP. OHM |
TEMP* RANGE °C |
NOM. CAP. PF/FT |
WT. 100FT. |
RG6/U TYPE | I | JRG-6FP | #18 CCS FOAM FEP .180 | AL/MYLAR +95% TC | FEP.250 | 75 | -55+ 200 | 17.0 | 5.5 |
RG58/U TYPE | A | JRG-58P | #20 SOLID FEP .107 | 1 TC 95% | FEP.159 | 50 | -55+ 200 | 27.5 | 2.9 |
RG58/UTHIN NET | A | JRG-58XFP | 19 X 32 TC FOAM FEP .095 | AL/MYLAR +95% TC | FEP.160 | 50 | -55+ 200 | 25.4 | 2.5 |
RG59/U TYPE | A | JRG-59P9 | #22 CCS FEP .135 | 1 BC 95% | FEP.205 | 75 | -55+ 200 | 21.0 | 6.2 |
RG59/U TYPE | A | JRG-59SFP | 7 X 30 BC FOAM FEP .146 | 1 BC 95% | FEP.216 | 75 | -55+ 200 | 16.0 | 5.9 |
RG59/U TYPE | A | JRG-59FP | #20 CCS FOAM FEP .140 | AL/MYLAR +95% TC | FEP.216 | 75 | -55+ 200 | 16.5 | 6.0 |
RG11/U TYPE | A | JRG-11FP | #14 BC FOAM FEP .285 | AL/MYLAR +60% TC | FEP.365 | 75 | -55+ 200 | 16.0 | 8.1 |
RG62A/U TYPE | C | JRG-62AP | #22 CCS AIR/FEP .146 | 1 BC 95% | FEP.220 | 93 | -55+ 200 | 12.8 | 6.0 |
RG62A/U TYPE | A | JRG-62AFP | #22 CCS FOAM FEP .146 | 1 BC 85% | FEP.225 | 93 | -55+ 200 | 12.5 | 5.9 |
RG59/U DUAL TYPE | – | JRG-DU59P | #23 CCS FEP .134 | 1 BC 97% | FEP.212 X .424 | 75 | -55+ 200 | 19.5 | 11.2 |
RG316/U DBL. SHIELD | B | †JRG-DS316P | 7 X .0067 SPCW PTFE .060 | 2 SPC 95% | FEP.114 | 50 | -55+ 200 | 29.2 | 9.3 |
78 OHM TWIN AXIAL | F | JRG-BL78P | 7 X 28 TC (2).152 | 1 TC 95% | FEP.220 | 78 | -55+ 200 | 16.9 | 5.3 |
100 OHM TWIN AXIAL | F | JRG-BL100P | 7 X 28 TC (2).209 | 1 TC 95% | FEP.252 | 100 | -55+ 200 | 13.3 | 9.4 |
100 OHM QUAD AXIAL | – | JRG-QX100P | #22 RC (4) | AL/MYLAR +70% TC | FEP.211 | 100 | -55+ 200 | 15.5 | 5.3 |